1. Operating Conditions
- Ambient temperature: 0 ℃ ~ +45 ℃
- Relative humidity: ≤ 85% RH
2. Measuring range and the constant value (RMS)
- Resistance: 0 ~ 2Ω (10mA), 2 ~ 20Ω (10mA), 20 ~ 200Ω (1mA)
- Voltage: AC 0 ~ 20V
3. Measurement accuracy and resolution
- Accuracy: 0 ~ 0.2Ω ≤ ± 3% ± 1d
- 0.2Ω ~ 200Ω ≤ ± 1.5% ± 1d
- 1 ~ 20V ≤ ± 3% ± 1d
- Resolution: 0.001Ω, 0.01Ω, 0.1Ω, 0.01V
4. Errors caused by auxiliary earth resistance and ground voltage measurement
- Allow auxiliary grounding resistance RC (C1 and C2 between)
0 ~ 2Ω, 2 ~ 20Ω ≤ 1KΩ
20 ~ 200Ω ≤ 2KΩ
RP (P1 and P2 between) <40KΩ error ≤ ± 5%
- Allow to voltage (rms frequency) ≤ 5V error ≤ ± 5%
5. Power
- maximum power dissipation≤ 2W
- DC: 8 × 1.5V (AA, R6) Battery
- AC: 220V/50Hz
6. Size and weight
- Host Size: 220mm * 200mm * 105mm
- Host Weight: ≤ 1.4kg